Choosing a biomaterials testing partner

To choose a biomaterials testing partner, start with what the data has to be good for, then ask questions that test it. Is your method on the lab’s accreditation scope? Does the study need GLP, which covers safety studies rather than basic exploratory studies of physical and chemical characteristics? How did the lab show the method fits your material? Can you get the raw data? How are samples tracked?

What should you settle before contacting a lab?

Settle what the data has to support, because that decides which of the questions below matter. FDA’s GLP rule, 21 CFR 58.1, applies to nonclinical studies “that support or are intended to support” applications for research or marketing permits. Write the use down in your study brief, and bring quality in before the study is scoped, as how a biomaterials pilot study works describes.

Which tests and sites does ISO/IEC 17025 accreditation include?

Accreditation covers the procedures and sites listed on the lab’s scope, and nothing beyond them. Ireland’s accreditation body explains how to read one in its guidance on interpreting scopes, and other bodies lay their scopes out differently. In INAB’s practice, the scope records the internal procedure that the accreditation covers, may also name the standard it’s based on, and identifies each permanent site by address, while customer sites where the lab tests aren’t listed. Each lab gets a registration number on its scope, which the guidance says lets end users “readily check the validity” of the services. Some labs hold a flexible scope, where the range, the matrices or the tests can be extended under a list the lab maintains, so ask for that list too.

Three checks follow: the method and matrix you need appear on the scope, the site that will run your samples is listed, and the accreditation body’s own directory shows the accreditation as current. The same guidance warns that how closely a lab’s procedure follows a standard varies, and that users “need to ensure that they are fit for its intended purpose.”

When do you need GLP, and when is development data enough?

You need GLP for a nonclinical study that determines a test article’s safety and supports an application. 21 CFR 58.3 defines a nonclinical laboratory study as one run “to determine their safety”, and the term excludes “basic exploratory studies carried out to determine whether a test article has any potential utility or to determine physical or chemical characteristics of a test article.” Degradation work needs a closer look, since degradation products can be a safety question for an absorbable material. Inside a GLP study, characterization doesn’t disappear: 21 CFR 58.105 requires the identity, strength, purity and composition of each batch of test article to be determined and documented. Outside the US, ask which GLP framework your regulator applies, such as the OECD Principles of GLP.

A GLP study carries an approved protocol, a study director and a quality assurance unit that signs a statement in the final report, and all three are in place before the study starts. Ask your regulatory lead which studies in your program need it before you choose a lab for any of them.

How was the method validated?

Ask how the lab showed the method is fit for your purpose on your kind of material. ICH Q2(R2) states the objective of validation as demonstrating “that the analytical procedure is fit for the intended purpose”, through characteristics such as specificity, range, accuracy and precision. It’s written for pharmaceuticals: its scope is release and stability testing of commercial drug substances and products, and it says its principles can be applied in a phase-appropriate way to procedures used during clinical development. A biomaterials development study sits outside that scope, and the questions still work: what range was tested, how repeatable were the readings, and what control or reference ran beside the samples. What makes a biomaterials dataset useful covers what to look for in the data itself.

Can you get the raw data?

Ask for the raw data before the study starts, and agree on its format. GLP defines raw data in 21 CFR 58.3 as the records “necessary for the reconstruction and evaluation of the report”, and says they may include “recorded data from automated instruments.” You can’t reconstruct a study from a summary table, so ask for the original instrument data with its metadata. FDA’s 2018 data integrity guidance calls FT-IR spectra and reprocessable chromatography data dynamic, and says a printout of them doesn’t preserve the complete original. A balance, by contrast, can produce a printout that’s itself the original.

The same guidance asks that data be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA). It defines an audit trail as a secure, computer-generated, time-stamped electronic record that lets someone reconstruct how a record was created, changed or deleted. That guidance was written for drug manufacturing, and its questions travel well: who recorded each value, when, and what changed afterward. For GLP studies, 21 CFR 58.190 requires archives “for orderly storage and expedient retrieval” of raw data, and 58.195 sets how long they’re kept. Ask any lab how long your records are kept and how you’d get them back.

How are your samples handled and tracked?

Ask how samples are received, labelled, stored and accounted for. Under GLP, 21 CFR 58.107 requires procedures for handling test and control articles so they’re stored properly, distributed without contamination, deterioration or damage, kept identified through distribution, and logged on receipt and distribution with the date and quantity of each batch. A development lab doesn’t have to follow that rule, and the same points make a sound chain of custody anywhere.

What belongs in the report and the agreement?

The report should let a reviewer judge the data without calling the lab. 21 CFR 58.185 lists what a GLP final report includes, among them “a description of all circumstances that may have affected the quality or integrity of the data”, the calculations performed on the data, and where the raw data is stored. Ask for the same in a development report.

The agreement should put confidentiality in place before composition detail changes hands, and say who owns the data, the formulations and any invention. Ask whether any test will be sent to another lab, since a subcontracted test runs under that lab’s scope and methods.

Which questions should a quality team ask a biomaterials testing lab?

Question to ask Why it matters What a good answer looks like
Is this method, on this matrix, at this site, on your accreditation scope? Accreditation covers only what the scope lists A current scope certificate, with the method and site named, that matches the accreditation body’s directory
Does this study need GLP? GLP covers safety studies and excludes basic exploratory studies of physical or chemical characteristics A clear answer tied to your data’s use, with GLP named only where the lab can run it
How did you show this method fits my material? Fitness for purpose is the point of validation The range tested, repeatability, and the control or reference run beside the samples
Will I get the raw data? A summary can’t be reconstructed Original instrument data with metadata, plus images where the method produces them
Who recorded each value, and what changed afterward? Data you can’t trace can’t be defended Records tied to a person or instrument and time, with changes logged
How are samples received, stored and tracked? Identity lost in handling is lost for good Logged receipt with date and quantity, stated storage conditions, and a plan for leftovers
What does the report include? A reviewer has to judge the data without calling the lab Methods, conditions, calculations, anything that may have affected the data, and where raw data is kept
What’s confidential, and who owns the results? Formulation detail is often the thing a competitor would most want An agreement signed before composition detail moves, with data and IP assigned to you

What a GelTech study measures on choosing a partner

A GelTech study measures how your material behaves over time in fluid: drained wet mass on Carousel, six samples at a time, with release, rheology and chemistry read on integrated instruments such as UV-Vis, HPLC, LC-MS, FTIR and rheometry. GelTech doesn’t run animal or clinical studies, and offers no accredited biocompatibility, sterility or safety testing.

When a project needs a confidentiality agreement, GelTech puts it in place first, and every dataset, formulation and invention from your studies belongs to your team. A formal quote lists the conditions, timepoints, replicates and report. Samples usually ship at room temperature, and leftovers are returned or disposed of. Carousel’s raw output is .csv data and .jpg images of each sample. Bring your quality questions to the scoping call.

Sources

Related reading

Questions

Does accreditation mean a lab's results are right for my study?

Accreditation shows a lab was assessed as competent for the activities on its scope, and it stops there. Ireland's accreditation body tells the people who use a lab's services that they need to make sure the service is fit for its intended purpose, so the match to your material and question is still yours to check.

What if a study later turns out to need GLP?

A non-GLP study isn't always shut out of a submission. For a device IDE, 21 CFR 812.27(b)(3) lets a sponsor include a nonclinical study that didn't comply with GLP, with a brief statement of the reason. Ask your regulatory lead how that applies to your program before you rely on it.

When should a quality team get involved in choosing a testing lab?

A quality team should get involved before the study is scoped, because what the data has to be good for decides which questions matter. Brought in after the report arrives, quality can only say whether the study fits a purpose nobody planned it around.

A row of palm trees against a blue sky

Need a material characterized?

Send your formulation and plan the study with the team.

By sending, you agree to our terms and privacy policy. Please leave out confidential formulation details until an NDA is in place.