Hydrogel swelling ratio: formulas and a worked example

The swelling ratio of a hydrogel is (Ws − Wd)/Wd: swollen mass minus dry mass, divided by dry mass, in grams of fluid per gram of polymer. By our arithmetic, a 40 mg dry disc that weighs 520 mg at equilibrium has a swelling ratio of 12 g/g, a Ws/Wd of 13 and an equilibrium water content of 92%.

Which formulas do labs use for a hydrogel swelling ratio?

Labs use six common forms, and two of them travel under the same name. Simões and colleagues write free swelling capacity as (Wt − Wdry)/Wdry in g/g. Richbourg, Peppas and colleagues call the inverse of the polymer mass fraction, Ws/Wd, the mass swelling ratio. Both forms get called a swelling ratio, so a reported number needs its formula beside it.

Formula name Expression What it reports When people use it
Swelling ratio (degree of swelling) (Ws − Wd)/Wd Grams of fluid taken up per gram of dry polymer Absorbency, superabsorbents, most formulation screens
Swelling percentage (Ws − Wd)/Wd × 100 The same, as a percentage Papers that report uptake in percent
Mass swelling ratio, Qm Ws/Wd Swollen mass per gram of dry polymer Network calculations, as the step to a volume fraction
Equilibrium water content (Ws − Wd)/Ws × 100 The share of the swollen gel that’s water Contact lenses, tissue scaffolds, comparing very wet gels
Volumetric swelling ratio, Qv Vs/Vd Swollen volume per unit dry volume Flory-Rehner and mesh size estimates
Polymer volume fraction, v2,s 1/Qv The share of the swollen volume that’s polymer Network theory inputs

Ws is swollen mass, Wd dry mass, Vs swollen volume and Vd dry volume. Swelling ratio and Qm differ by exactly 1, so a value of 12 and a value of 13 can describe the same gel.

How do you convert mass swelling to volumetric swelling?

You convert through the densities of the polymer and the fluid. Richbourg and colleagues describe this mass-based route, from polymer mass fraction to volume fraction using literature densities, as common practice for hydrogels. Written as a volumetric swelling ratio, and assuming the polymer and water volumes simply add, the calculation is:

Qv = 1 + (Qm − 1) × ρp / ρs

where ρp is the dry polymer density and ρs is the fluid density. Richbourg and colleagues found the mass-based route broadly sufficient for synthetic gels with well-characterized densities, and not viable for gelatin methacrylamide, where they measured volume by buoyancy instead.

Yang, Dargaville and Hutmacher measured volume from disc dimensions in microscope images instead, with a larger error than weighing.

How does the worked example come out?

Take a disc that weighs 40 mg dry and 520 mg at equilibrium. Every number below is our arithmetic.

  1. Swelling ratio: (520 − 40) / 40 = 480 / 40 = 12 g/g.
  2. Mass swelling ratio: 520 / 40 = 13.
  3. Swelling percentage: 12 multiplied by 100, or 1,200%.
  4. Equilibrium water content: (520 − 40) / 520 = 0.923, or 92.3%.
  5. Volumetric swelling ratio: with an assumed polymer density of 1.1 g/mL and water at 1.0 g/mL, 1 + (13 − 1) × 1.1 = 14.2.
  6. Polymer volume fraction: 1 / 14.2 = 0.070, so about 7% of the swollen volume is polymer.

The same gel reads 12, 13, 1,200% or 92.3% depending on the formula. Step 6 is the input that Flory-Rehner estimates of mesh size start from.

How do you run a swelling test at the bench?

You dry, weigh, immerse, then lift, remove surface fluid and weigh at set times until the mass stops changing. Simões and colleagues air-dried their hydrogels to constant weight, immersed them, and removed excess surface water with absorbent paper before each weighing, taking equilibrium at 24 hours. Yang and colleagues weighed from 5 minutes to 7 days at 37 °C. Their swelling ratio dipped between 3 and 24 hours as the uncrosslinked fraction, 11.4% of the gel, washed into the medium, then held steady from 24 hours.

  • Dry: to constant weight, by air, oven or freeze-drying. Name the method, since residual water inflates Wd and shrinks every ratio. Richbourg and colleagues desalted their buffer-swollen gels in water before vacuum drying, so salt didn’t count as polymer.
  • Immerse: in a stated medium, with a fluid volume large enough that uptake doesn’t change its composition.
  • Hold temperature: state it, since 37 °C and room temperature are both common.
  • Remove surface fluid: blot or drain the same way every time. A hard blot pulls water from the gel, and a light one leaves a film on it.
  • Weigh on a schedule: close together early, when the curve is steep, and further apart later.
  • Call equilibrium: when readings stop moving in either direction, after any early drop from the soluble fraction, rather than at a fixed hour. Weigh the dry mass after swelling as well as before if the gel has a sol fraction.

What changes the swelling ratio besides the gel?

The test fluid changes it, and most for a charged superabsorbent. In Simões’s study, a commercial diaper superabsorbent swelled to about 295 g/g in deionized water and about 20 g/g in synthetic urine, while most of the authors’ cellulose gels, at 6.9 to 7.5 g/g, changed little between the two fluids. Neutral gels respond too. Yang and colleagues expected PEG-diacrylate to be less sensitive to salt than polyelectrolyte gels, yet every formulation they tested swelled less as ionic strength rose, which they describe as considerable sensitivity.

Li and Mooney list pH and temperature among the cues that trigger swelling, so a water number and a buffer number belong in separate columns. Free swell against absorption under load is a separate comparison with its own page.

Where do published definitions disagree?

They disagree on the reference state, the denominator and the clock. Yang and colleagues calculate gravimetric swelling as (Ws − Wi)/Wi, where Wi is the weight right after crosslinking, and keep dry mass for the water content alone. That ratio starts from a gel that already holds water, so it comes out smaller than one measured from dry mass. Both states carry information: Richbourg and colleagues’ Flory-Rehner calculation needs the relaxed polymer volume fraction, as made, and the swollen one, so a network estimate uses the as-made reference alongside the dry one.

  • Reference state: dry, as made, or both. Two ratios with different references can’t be compared directly.
  • Denominator: dry mass for swelling ratio, swollen mass for water content.
  • Units: g/g against percent.
  • Clock: Simões took equilibrium at 24 hours. Yang’s ratio held steady from 24 hours, and they report equilibrium at day 7, their last timepoint.

Report these next to the number, with the formula, medium and temperature.

What are the limits of one swelling ratio?

A single equilibrium ratio can’t show how the gel got there or what happens next. Two formulations can both reach 12 g/g, one in an hour and one in three days. Li and Mooney note that mesh size grows as a network degrades, so a degrading gel can gain water while it loses polymer. For wet against dry mass, see the guide to polymer degradation testing. To rank candidates fairly, see comparing hydrogel formulations.

What a GelTech study measures on swelling

Carousel records swelling as a curve, weighing each sample in its chamber at every timepoint, to 1 mg, six samples at a time. Free fluid drains through a filter before each weighing, so the reading is drained wet mass. With consistent handling at every reading, Carousel’s mass data carries roughly 3x less data variability than manual work.

The 40 mg disc clears Carousel’s 25 mg minimum dry sample. By our arithmetic, a 1 mg error in swollen mass moves its swelling ratio by 0.025 g/g (1 mg over 40 mg), and a 1 mg error in dry mass moves it by about 0.33 g/g (520 mg over 40 mg squared), so the dry mass needs the most care. Automated hydrogel swelling measurement explains how drain-and-weigh compares with other automated methods. GelTech doesn’t run animal or clinical studies, or accredited biocompatibility or sterility testing. See R&D services and how a pilot study works.

Sources

Related reading

GelTech services and industries

Questions

Should I report swelling ratio as g/g or as a percentage?

A swelling ratio in g/g and a swelling percentage carry the same information, since the percentage is the ratio times 100. Pick one and don't mix the two in one table.

How does crosslink density change the swelling ratio?

Crosslink density lowers the swelling ratio, because a tighter network resists stretching. In PEG-diacrylate gels, Yang and colleagues saw equilibrium swelling, measured against the as-made gel, rise with the PEG chain's molecular weight, which spaces the crosslinks further apart, and rise with polymer weight fraction across 10 to 30%.

Can hydrogel volume be measured without knowing the polymer density?

Hydrogel volume can be measured without the polymer's density by weighing the gel in air and again submerged in a nonsolvent such as heptane. Richbourg and colleagues used that buoyancy method, which needs only the nonsolvent's density, and found it necessary for gelatin methacrylamide gels.

A row of palm trees against a blue sky

Need a material characterized?

Send your formulation and plan the study with the team.

By sending, you agree to our terms and privacy policy. Please leave out confidential formulation details until an NDA is in place.