Free swell versus absorption under load
Free swell measures how much fluid a wound dressing takes up in excess test fluid with no load on it. Absorption under load, which EN 13726:2023 calls absorption under compression, measures uptake while a weight already presses on the dressing. Both soak for 30 minutes. Free swell is a normative method, and absorption under compression is informative because interlaboratory trials showed unexplained variation.
How does the free swell test work?
The free swell test soaks a dressing in excess test fluid with no load, then weighs the fluid it holds. EN 13726:2023 defines free swell absorptive capacity as “total absorptive capacity in the presence of excess test liquid and in the absence of any applied load”. Annex A explains three of its settings:
- Intact dressings: the 2023 test allows a whole dressing, because sectioning a super-absorbent dressing could leach polymer and lower the result.
- Edgeways entry: the dressing now goes into the fluid obliquely, which the working group found cuts air pockets on its surface.
- Time: incubation is 30 minutes, based on earlier UK work.
The unit follows the format: grams and grams per square centimeter for an intact dressing, grams per square centimeter for a sectioned sheet, and grams per gram for rope or ribbon. Nygren, Malone and Gefen, two Mölnlycke employees and a paid Mölnlycke consultant, point out that fluid reaches the dressing from several sides in this test, while exudate reaches it only from the wound side.
What does absorption under load measure?
Absorption under load measures how much fluid a dressing takes up while pressure is already on it. Annex A of EN 13726:2023 gives the reason it was added: “Many dressings are now designed to be used under compression bandages/hosiery”, and the 2002 parts had no way to test that. Annex D “simulates a dressing under pressure before absorbing fluid”.
It’s a different question from fluid retention in Annex C, which “simulates a dressing which has absorbed and then exposed to pressure”, such as a patient rolling onto a sacral dressing. Order matters:
- Absorption under compression: load first, then fluid. It reads what the pressed dressing can take up.
- Fluid retention: fluid first, then load. It reads what a full dressing gives back.
The standard reports both pressures in mmHg, the unit clinicians use for compression garments, and gives 1 mmHg as 133 Pa. For scale, a 2025 review describes a lab wound simulator whose compression is typically set at 20 to 40 mmHg, to simulate what compression bandaging delivers on venous leg ulcers. Clause 4 calls Annexes C and D “optional additional tests”, and Annex A says they’re informative “as inter-laboratory experiments have shown unexplained variation, especially between laboratories.”
Why might free swell and absorption under load rank dressings differently?
The two tests can rank dressings differently because pressure can take away space a dressing would otherwise fill, and materials may differ in how much they keep under it. An expert review of foam dressing standards, published online in 2022, lists as a gap in the 2002 absorbency part of EN 13726 that its free swell measures ignore how body weight or external forces can distort the dressing and reduce its reservoir. The panel behind it was supported by an educational grant from Mölnlycke Health Care, a dressing manufacturer.
Superabsorbent polymer chemistry shows how such a trade-off can arise. Kwon, Kim and Kim, citing earlier work, write that raising crosslinking to improve absorbency under load can “often cause significant reductions” in centrifuge retention capacity. In their itaconic-acid powder, raising the surface crosslinker from 0.5 to 1.5 wt% lowered retention and raised absorbency under load. Above 1.5 wt% both reversed, which they put down to side reactions. Their best balance was 33.8 g/g centrifuge retention against 18.8 g/g under a 0.3 psi load.
That’s one powder, and centrifuge retention isn’t free swell, so it shows a possible mechanism rather than a dressing ranking. No dressing-level study in the sources checked here shows two dressings swapping order between the tests, so a reversal is a reason to run both rather than an expected result.
| Feature | Free swell | Absorption under load |
|---|---|---|
| EN 13726:2023 annex | B, normative | D, informative |
| Load | None | Applied before fluid |
| Question it answers | Most fluid the dressing holds | Fluid it takes up while pressed |
| Clinical picture | No external pressure | Dressing under a compression bandage or hosiery |
| Incubation | 30 minutes | 30 minutes |
| Superabsorbent powder parallel | NWSP 240, ISO 17190-5 | NWSP 242, ISO 17190-7 |
Which test choices change the result?
Load, timing, fluid and sample form each move the number, and each has a cost. Clause 5 of EN 13726:2023 says any deviation from a test parameter is validated by the lab and noted in the report.
- Load: match it to the bandage or body weight the dressing will see, and state it in both units. A heavier load sits closer to strong compression and leaves less uptake to tell dressings apart. Powder methods quote psi and the dressing annexes quote mmHg: 0.3 psi is about 16 mmHg and 0.7 psi about 36 mmHg, by our arithmetic (1 psi as 6,895 Pa, 1 mmHg as 133 Pa).
- Timing: 30 minutes is the annex endpoint. Hasatsri and colleagues followed free swell for 12 hours, by a modified 2002 method. One alginate reached the highest uptake of six dressings and degraded after about 4 hours, and another degraded after about an hour. A longer run shows rate and breakdown, and takes more time per sample.
- Fluid: Solution A is the reference in a dispute. Annex A item 13 lets a lab use another fluid that simulates exudate, as a noted deviation with its reason. Svensby and colleagues, from Mölnlycke’s R&D group with Gefen and Breda Cullen as paid consultants, found protein-containing fluids lowered 24-hour fluid handling capacity (Annex E) for half of eight foam dressings. They didn’t test free swell or compression, and protein fluid results won’t compare directly with Solution A data.
- Sample: an intact dressing keeps its construction, and a cut piece fits more apparatus. Report the absorbent area either way.
Which clinical conditions do both tests leave out?
Neither test shows how a dressing performs at the partial saturation it sees on a patient. Annex A item 7 says so itself: the absorption tests use fully saturated dressings, which “is rarely the clinical situation”, and breathable backings leave a dressing partly saturated in use. Nygren and Gefen, a Mölnlycke employee and a paid Mölnlycke consultant, add that the fluid retention test ignores fluid moving within the dressing. Gravity on a leg, one-way flow from the wound, and real exudate are outside both. Vapor loss is its own test, covered in MVTR for wound dressings. How these tests fit a full fluid handling claim is in wound dressing fluid handling, and the arithmetic of mass gain is in the hydrogel swelling ratio.
What a GelTech study measures on free swell and absorption under load
A GelTech study runs both on one platform, on a test menu aligned with EN 13726. Carousel runs absorption under load at 0.3 to 0.7 psi, and weighs each sample to 1 mg at every reading, six samples at a time, so you see the uptake curve on the way to the endpoint. Its mass data carries roughly 3x less data variability than manual work. Which load to use is agreed with you against the bandage or body weight your dressing will see.
GelTech doesn’t run clinical or animal studies, or sterility or biocompatibility testing. See wound dressing testing and how a pilot study works.
Sources
- CEN. EN 13726:2023 Test methods for wound dressings: aspects of absorption, moisture vapour transmission, waterproofness and extensibility. Foreword, definitions, clauses 4 and 5 and Annex A, in the SIST EN 13726:2024 preview
- Nygren E, Malone M, Gefen A. Laboratory evaluations of wound dressings: key advances to reflect clinical reality. Int Wound J. 2025;22(S1):e70333
- Nygren E, Gefen A. Little news is good news? What is missing in the recently published EN 13726:2023 test standard for wound dressings. Int Wound J. 2024;21(3):e14787
- Gefen A, Alves P, Beeckman D, et al. How should clinical wound care and management translate to effective engineering standard testing requirements from foam dressings? Adv Wound Care. 2024;13(1):34-52
- Kwon YR, Kim JS, Kim DH. Effective enhancement of water absorbency of itaconic acid based-superabsorbent polymer via tunable surface-crosslinking. Polymers. 2021;13(16):2782
- Svensby AU, Nygren E, Gefen A, et al. The importance of the simulated wound fluid composition and properties in the determination of the fluid handling performance of wound dressings. Int Wound J. 2024;21(5):e14861
- Hasatsri S, Pitiratanaworanat A, Swangwit S, Boochakul C, Tragoonsupachai C. Comparison of the morphological and physical properties of different absorbent wound dressings. Dermatol Res Pract. 2018;2018:9367034
Related reading
GelTech services and industries
Questions
What is absorbency under load (AUL)?
Absorbency under load (AUL) is the fluid a material takes up while a set weight presses on it, reported in grams per gram for superabsorbent powders. The powder methods are NWSP 242 and ISO 17190-7. EN 13726:2023 calls the dressing version absorption under compression.
Is free swell the same as swelling ratio?
Free swell and swelling ratio both come from weighing a sample before and after it takes up fluid, and they report the gain differently. Free swell in EN 13726:2023 is a capacity in grams, grams per square centimeter or grams per gram, depending on the dressing format. A swelling ratio divides the gain by dry mass.
Which is better for an absorbency claim, free swell or absorption under load?
An absorbency claim for a dressing used under a compression bandage is better backed by both tests than by either alone. Free swell is the normative method and gives the reference capacity, and absorption under compression shows what the dressing takes up when the pressure comes first. Name both, with their status.