Self-driving labs for biomaterials

A self-driving lab runs a closed loop: robots make and measure samples, and a model, often Bayesian optimization, picks the next experiment. Published polymer loops get results within hours; one flow platform ran reactions with residence times of 4 to 20 minutes. A PLGA degradation study can run ten weeks, so a depot loop gets fewer cycles, on samples that change while they’re measured.

What is a self-driving lab?

A self-driving lab automates the experiment and also plans the next one. The 2024 Chemical Reviews survey of self-driving laboratories by Tom and colleagues defines it by those two parts, automated experimental workflows and autonomous experimental planning, and calls Bayesian optimization one of the most common planning strategies today.

The loop has four steps:

  1. Make: a robot or flow reactor prepares the formulation.
  2. Measure: an instrument reads the property you care about, ideally without a person in between.
  3. Learn: a surrogate model, often a Gaussian process, is fit to every result so far. It predicts the property for untested recipes with an uncertainty on each prediction.
  4. Decide: an acquisition function weighs predicted value against uncertainty and proposes the next batch.

The review notes that Gaussian process models train quite well with small amounts of data.

The decide step balances two pulls. Exploring tests recipes the model knows little about, and exploiting tests the ones it already rates highest. Tamasi and colleagues, below, used expected improvement plus clustering to spread their first four rounds across different chemistries, then filled the fifth round with the copolymers ranked highest by predicted activity. A loop with few rounds to spend has to choose that balance early.

Which self-driving labs have worked on polymers and soft materials?

Closed loops have run polymer synthesis, polymer-protein formulation and hydrogel mechanics. In Knox’s and Tamasi’s loops, each result came back within hours.

  • Polymer synthesis: Knox and colleagues ran RAFT polymerizations in a computer-controlled flow reactor, with online benchtop NMR and inline GPC. Ten space-filling runs trained the first model. A multi-objective Bayesian algorithm then proposed four runs at a time, inside limits of 4 to 20 minutes’ residence time and 80 to 116 °C, mapping the trade-off between conversion and dispersity with no user input.
  • Polymer-protein hybrids: Tamasi and colleagues used a liquid-handling robot to make copolymers in 96-well plates, mixed them with enzymes, heated them for 30 minutes to an hour, and assayed retained activity. After a 504-copolymer screen, a Gaussian process proposed 24 candidates per round for five rounds, for each enzyme.
  • Hydrogels: the abstract of Liu and colleagues’ 2024 autonomous experimentation paper reports consensus Bayesian optimization finding mechanically optimized composite polysaccharide hydrogels within a budget of eight iterations.

In the papers checked here, none of these loops measured swelling, degradation or release over weeks.

Why are soft biomaterials a hard case for a self-driving lab?

For a PLGA or other polyester depot, the degradation readouts take weeks, and the sample changes while you wait. Lu, Garcia and Mikos followed PLGA films in PBS at 37 °C for 10 weeks. Weight held for the first several weeks, then fell sharply, while molecular weight fell as soon as the films went into buffer. They also saw degradation during sample processing.

By our arithmetic from that 10-week window, a loop that waits for mass loss gets about one round every couple of months. Batching helps: Tamasi and colleagues ran 24 candidates per round.

The field’s other answer is an early proxy. The Tom review names multi-fidelity optimization for experiments too costly to run in full. Attia and colleagues closed a loop on battery lifetime, which takes months to years to measure, by predicting it from the first few cycles. They found good protocols among 224 candidates in 16 days, against over 500 days for an exhaustive search without early prediction. In Lu’s films, molecular weight moved long before mass did, so it’s a candidate proxy. A proxy still has to be validated against the full readout, as Attia’s team did, before a loop trusts it.

Three more problems stack on top:

  • Wet, changing samples: Deng and Uhrich saw fluid uptake and specimen dimensions grow over six weeks while molecular weight fell, and absorbed fluid changed the storage modulus. Water in the sample is part of the reading.
  • Measurement noise: blotting and weighing by hand vary between people and days, and where manual tests vary covers the steps. Knox and colleagues, citing earlier work, note that Bayesian methods suit noisy, expensive data. Noise still costs cycles, since the model has to learn it too.
  • Several properties at once: swelling, degradation, release and mechanics move together and can trade off.
Loop stage What it needs What makes it hard for biomaterials
Make Automated, repeatable preparation of each formulation Gels cure, cross-link and age, and processing itself can start degradation
Measure A readout in minutes to hours, with no hand step Degradation and release of a polyester depot run for weeks; wet mass depends on how fluid is drained
Learn Enough clean points to fit a model and its uncertainty Few rounds per year, and replicate noise on a scale with the effect
Decide A clear objective, or a stated trade-off Several properties shift together over time, so the target is a curve rather than one number

What does the data need before a model can use it?

A model needs to know what each number is: the material and batch, the conditions, the handling, the timepoint and the units. The Tom review calls for FAIR data in self-driving labs and notes a lack of tradition in publishing chemical results in structured, open databases.

Failures belong in the record too. Tamasi and colleagues left copolymers that gelled out of their model’s training data and later added a classifier to predict gelation. A record that drops failed samples without a note teaches a model that they never happened. What makes a biomaterials dataset useful covers the fields, raw against processed data and replicate structure.

Where does AnGel sit in a self-driving lab?

AnGel covers parts of two steps: planning a screening run and checking whether a dataset is ready to model. The Tom review describes real self-driving labs at different levels of automation, and a tool can serve some steps of the loop without running all of them.

AnGel AI is in beta. Its experiment planner lays out hundreds of formulations across well plates, so one run maps the space, and it flags missing replicates and checks that inputs vary independently. Its Data and Models tool runs a quality and predictability check on a dataset you upload, and a team’s own models are built from its own data once that data is ready. The model shown on the AnGel page is a demo on synthetic data. Client data is never used to train shared models.

What a GelTech study measures for a self-driving lab

A GelTech study adds measured curves on the slow readouts. Carousel runs six samples at a time, around the clock, and records drained wet mass at every timepoint, with pH and temperature monitored in line and an image of every sample. For PLGA and other soluble polymers, GelTech measures molecular weight in-house on separate samples, beside the mass curve. Integrated instruments such as UV-Vis, HPLC, LC-MS, FTIR and rheometry read release, chemistry and mechanics. GelTech doesn’t run animal or clinical studies, or accredited biocompatibility or sterility testing. See the platform, what to automate first and how a pilot study works.

Sources

Related reading

GelTech services and industries

Questions

Is a self-driving lab the same as high-throughput screening?

A self-driving lab differs from high-throughput screening in who plans the next experiment. A screen runs a design fixed up front, while a self-driving lab updates its model after each round and plans the next batch from it. A screen often comes first, to give the model its starting data.

Does a self-driving lab have to automate every step?

A self-driving lab doesn't have to automate every step. The 2024 Chemical Reviews survey describes real examples at different levels of automation, so a loop with a person moving samples between instruments still counts as a partly autonomous lab.

Can a self-driving lab handle more than one goal at once?

A self-driving lab can optimize several goals at once by mapping a Pareto front, the set of results where one goal can't improve without the other getting worse. The output is a trade-off curve for the team to choose from, rather than a single best recipe.

A row of palm trees against a blue sky

Need a material characterized?

Send your formulation and plan the study with the team.

By sending, you agree to our terms and privacy policy. Please leave out confidential formulation details until an NDA is in place.